
US Structural Design & ACI 318-25 Excel Suite – 18 Engineering Workbooks (US Customary Units)
What's Included
The complete US engineering calculation suite: 18 fully unlocked, transparent structural engineering workbooks formatted in native US Customary Units (in, ft, kips, psi, psf). Designed in rigorous compliance with ACI 318-25, IBC 2024, ASCE 7-22, AISC 360-22, and NDS 2024.
Instant Digital Access
Direct file download immediately after checkout. Access anytime under My Account.
Verified & Standard Compliant
Spreadsheets, tools, and code templates are fully tested for technical accuracy.
Dedicated Support
Direct technical assistance via Telegram @hungthinhvn or Email hangchat.xyz@gmail.com
Product Description
COMPLETE US CUSTOMARY SUITE • 18 WORKBOOKS
Verified Edition: 2026 Release • ACI 318-25 / IBC 2024 / ASCE 7-22
US Structural Design & ACI 318-25 Engineering Excel Suite
A complete professional calculation collection containing 18 fully unlocked, transparent engineering workbooks configured strictly in US Customary Units (inches, feet, pounds, kips, psi, psf, pcf). Covering structural concrete members, deep pier foundations, earth retaining structures, steel connection kinematics, lateral diaphragms, timber design, and wind pressure calculations, every file features open cell formulas for effortless auditing and project verification.
Complete Master Directory: All 18 Included Workbooks
Every workbook listed below is verified, tested, and bundled inside US-Structural-Design-ACI-318-25-Excel-Suite-18-Workbooks.zip.
18 of 18 Modules Included
| No. | Workbook Title & File Name | Design Standards | Core Engineering Checks & Formulation | Units |
|---|---|---|---|---|
| 01 |
Isolated Column Footing Design 01-Column Footing Design Based on ACI 318-25 – US Units.xlsx |
ACI 318-25 ASCE 7-22 Ch. 2 | Biaxial soil bearing pressure (qmax ≤ qa), two-way slab punching shear (φ = 0.75), one-way wide beam shear, flexural steel in long/short directions, crack control maximum spacing (s ≤ 18 in), column-to-footing dowel bearing (φ = 0.65), and tension/compression development lengths ld / ldh. | in, ft, kips, psf |
| 02 |
Cantilever Retaining Wall (Dual Sheets) 02-Concrete Retaining Wall Based on ACI 318-25 – US Units.xlsx |
ACI 318-25 IBC 2024 Ch. 18 | Dual independent calculation sheets: WITH WATER (submerged soil, hydrostatic buoyant pressures) and WITHOUT WATER. Overturning factor (FS ≥ 1.50), sliding factor (FS ≥ 1.50), shear key passive resistance, stem flexure & shear, toe/heel reinforcement, and shrinkage control. | in, ft, kips, pcf |
| 03 |
Reinforced Concrete Corbel & Bracket 03-Corbel Design Based on ACI 318-25 – US Units.xlsx |
ACI 318-25 Sec. 16.5 Table 21.2.1(e) | Geometry span-to-depth check (av/d ≤ 1.0), unified strength reduction φ = 0.75, upper shear cap Vn ≤ min[0.2 f’c bw d, (480 + 0.08 f’c) bw d, 1600 bw d], shear-friction steel Avf, direct horizontal tension An (Nuc ≥ 0.2 Vu), primary tension tie As, and closed stirrups Ah. | in, kips, ksi, psi |
| 04 |
Diagonally Reinforced Coupling Beam 04-Coupling Beam Design Based on ACI 318-25 – US Units.xlsx |
ACI 318-25 Sec. 18.10 Sec. 18.7.5 Confinement | Seismic aspect ratio verification ℓn / h < 2, intersecting diagonal bar bundle capacity Vn = 2 Avd fy sinα ≤ 10√(f’c) Acw (φ = 0.85), transverse confinement ties Ash per Section 18.7.5.4, longitudinal skin reinforcement, and stirrup spacing along clear span. | in, ft, kips, ksi |
| 05 |
Concrete Deep Beam (Strut-and-Tie) 05-Deep Beam Design Based on ACI 318-25 – US Units.xlsx |
ACI 318-25 Sec. 9.9 Chapter 23 (STM) | Span classification ℓn ≤ 4h, Section 9.9.2.1 max shear ceiling Vu ≤ φ 10√(f’c) bw d, Strut-and-Tie tension tie design force Tu, primary bottom bar selection, CCT and CCC nodal zone bearing checks, and orthogonal distributed web steel ratios (ρ ≥ 0.0025). | in, ft, kips, ksi |
| 06 |
Flagpole & Drilled Pier Footing 06-Flagpole Footing Design Based on IBC & ACI 318-25 – US Units.xlsx |
IBC 2024 Sec. 1807.3 UBC 97 Chapter 18 | Round and square drilled pier shaft embedment. Non-constrained formulation d = 0.5 A [1 + √(1 + 4.36 h / A)] & constrained formula d2 = 4.25 P h / (S3 b). Lateral soil bearing resistance S1/S3, concrete flexural shear, and dowel cage detailing. | in, ft, lbs, psf/ft |
| 07 |
Special Structural Shear Wall 07-Shear Wall Design Based on ACI 318-25 – US Units.xlsx |
ACI 318-25 Sec. 18.10 Chapter 11 & 22 | In-plane shear capacity Vn = Acv [αc λ √(f’c) + ρt fy], boundary element triggers (displacement-based c ≥ ℓw / [600 (δu / hw)] and stress-based fc ≥ 0.2 f’c), transverse confinement Ash / (s bc), and full P-M interaction diagram. | in, ft, kips, ksi |
| 08 |
Continuous Wall Strip Footing 09-Wall Footing Design Based on ACI 318-25 – US Units.xlsx |
ACI 318-25 Ch. 13, 14 ASCE 7-22 | Linear wall strip foundation analysis. Service bearing pressures for gravity and lateral load combinations, eccentricity kernel checks (e ≤ B/6), one-way transverse cantilever shear, bottom flexural reinforcement As, longitudinal distribution steel, and plain unreinforced concrete provisions. | in, ft, kips, klf |
| 09 |
One-Story Wall Lateral Force (IBC) 10-Lateral Force for One-Story Wall Based on IBC – US Units.xlsx |
IBC 2024 / IBC 2000 ASCE 7-22 Ch. 12/13 | Out-of-plane seismic lateral forces for single-story perimeter structural walls (concrete, masonry, tilt-up). Formulates Fp = 0.4 SDS Ie Ww ≥ 0.1 Ww, anchorage forces to roof diaphragm, mid-height flexural bending moment, ledger connection loads, and out-of-plane deflections. | in, ft, kips, plf |
| 10 |
One-Story Wall Lateral Force (UBC) 11-Lateral Force for One-Story Wall Based on UBC – US Units.xlsx |
UBC 97 Sec. 1632 Historic Code Audit | Comparative lateral seismic force determination on one-story perimeter walls. Formulates Fp = [ap Ca Ip / Rp] (1 + 3 hx/hr) Wp, diaphragm boundary reaction loads, wall inertial forces, and anchor bolt pull-out/shear resistance for historical audits and retrofits. | in, ft, lbs, plf |
| 11 |
Eccentric Welded Connection (AISC) 12-Weld Capacity of Eccentric Connection Based on AISC-ASD – US Units.xlsx |
AISC 360-22 AISC ASD Chapter J | Four distinct weld geometry worksheets: CASE 1 (Dual vertical welds), CASE 2 (C-shaped 3-sided), CASE 3 (Box 4-sided), and CASE 4 (L-shaped). Evaluates polar moment of inertia, elastic vector method & ICR method, effective throat shear, and minimum/maximum weld sizes. | in, kips, kips/in |
| 12 |
WF Beam Opening Reinforcement Check 13-Check Reinforcement of WF Beam at Opening – US Units.xlsx |
AISC Design Guide 2 AISC 360 Specification | Wide-flange steel beams with rectangular web cutouts. Verifies local web shear buckling, Vierendeel bending across top and bottom tees, net section tensile yielding, compression buckling of tee stems, horizontal weld sizing for reinforcement bars/plates, and interaction envelopes. | in, kips, kip-in |
| 13 |
Wind Load Analysis Engine (ASCE 7) 14-Wind Analysis Based on ASCE 7 – US Units.xlsx |
ASCE 7-22 ASCE 7-98 Ch. 6, 26-31 | Dual dedicated analytical modules: (1) Low-rise Building (h ≤ 60 ft); (2) Building with h > 60 ft. Calculates velocity pressure qz = 0.00256 Kz Kzt Kd Ke V2, exposure categories (B, C, D), external/internal pressure coefficients (Cp, GCpi), MWFRS & C&C loads. | ft, mph, psf |
| 14 |
Wood Beam Design (NDS) 15-Wood Beam Design Base on NDS – US Units.xlsx |
AWC NDS 2024 IBC 2024 Ch. 23 | Sawn lumber and glulam timber flexural member design. Calculates adjusted reference values (F’b = Fb × CD CM Ct CL CF Cfu Ci Cr, F’v, E’). Verifies extreme fiber flexural stress, horizontal shear parallel to grain, bearing at supports (F’c⊥), and L/360, L/240 deflections. | in, ft, lbs, psi |
| 15 |
Wood Column & Post Design (NDS) 16-Wood Column Design – US Units.xlsx |
AWC NDS 2024 NDS Chapter 3 & 4 | Solid wood posts, timber columns, and built-up studs subjected to concentric axial compression and combined axial plus transverse bending. Calculates column stability factor CP, slenderness ratio ℓe / d ≤ 50, Euler buckling FcE, and full P-M interaction (fc/F’c)2 + [fb / (F’b (1 – fc/FcE))] ≤ 1.0. | in, ft, lbs, kips |
| 16 |
Wood Diaphragm Design (SDPWS & ACI) 17-Wood Diaphragm Based on ACI 318-25 – US Units.xlsx |
IBC 2024 / SDPWS 2021 ACI 318-25 Transfer | Horizontal wood structural panel (WSP) roof and floor diaphragms. Calculates unit shear demand v = V / 2b (plf), fastener schedule (sheathing nail diameter and spacing), blocked vs unblocked layouts, chord tension & compression forces (T = C = M / b), collector drag struts, and mid-span deflections. | in, ft, lbs, plf |
| 17 |
Wood Shear Wall Design (SDPWS & ACI) 18-Wood Shear Wall Based on ACI 318-25 – US Units.xlsx |
IBC 2024 / SDPWS 2021 ACI 318-25 Ch. 17 Anchors | Vertical wood structural panel shear walls resisting seismic and wind shear. Unit shear capacity (plf), sheathing thickness, perimeter nail spacing, overturning hold-down tension anchor force (T = [MOT – 0.6 MR] / dw), anchor bolt shear/tension embedment into concrete footing per ACI 318-25, and drift checks. | in, ft, lbs, kips |
| 18 |
Two-Way Slab Punching Shear (US Units) 19-Slab Punching Design – US Units.xlsx |
ACI 318-25 Sec. 22.6 ACI 318-19 / ACI 318-08 | Two-way slab-column punching shear evaluation for interior, edge, and corner columns in US Customary units. Calculates critical shear perimeter bo at d/2, concrete two-way shear capacity vc = min[(2 + 4/β), (2 + αs d / bo), 4] λs λ √(f’c), size-effect factor λs, and polar moment of inertia Jc. | in, kips, psi |
Disciplines Covered Across the 18 Engineering Modules
ACI 318-25 & ASCE 7-22 Concrete
Complete coverage for shallow isolated & strip wall footings, cantilever retaining walls with water table, corbel brackets, seismic coupling beams, Strut-and-Tie deep transfer beams, special shear walls with P-M curves, and flat plate punching shear.
AISC 360-22 & IBC Pier Embedment
Evaluates drilled pier flagpole/sign shafts under constrained and non-constrained ground conditions, 4 weld configurations under eccentric shear and torsional moments, and Vierendeel web openings in wide-flange beams.
AWC NDS 2024 & SDPWS 2021
Sawn lumber and glulam flexural beams with NDS adjustment factors, solid timber column stability (CP) with biaxial P-M interaction, horizontal wood structural panel (WSP) diaphragms, and wood shear walls with foundation hold-down anchors.
ASCE 7-22, IBC 2024 & UBC 97
Full analytical wind pressure calculations for low-rise and high buildings under ASCE 7-22, paired with out-of-plane seismic wall forces and diaphragm boundary reactions conforming to IBC 2024 and comparative UBC 97 provisions.
Engineering Transparency & Software Compatibility
Customer Reviews
Based on 2 reviews
Sarah P
Nov 29, 2024As a civil engineer, these templates save me so much time. From concrete footings to lateral force analysis, everything I need is right at my fingertips. Highly recommend!
Emily R
Nov 20, 2024I've been using these templates for a week now, and they are perfect for my foundation design calculations. The wind analysis and lateral force templates are particularly helpful. So glad I bought this bundle!